ACS550-01/U1 User’s Manual 85
Application macros
ACS550-U1
Parameter
ABB
Standard
3-wire Alternate
Motor
Potenti-
ometer
Hand-auto
PID
Control
PFC
Control
Torque
Control
9902
APPLIC MACRO 1=
ABB STANDARD
2=
3-WIRE
3=
ALTERNATE
4=
MOTOR POT
5=
HAND/AUTO
6=
PID CONTROL
7=
PFC CONTROL
8=
TORQUE CTRL
9904 MOTOR CTRL
MODE
3= SCALAR:
FREQ
1= VECTOR:
SPEED
1= VECTOR:
SPEED
1= VECTOR:
SPEED
1= VECTOR:
SPEED
1= VECTOR:
SPEED
3= SCALAR:
FREQ
2= VECTOR:
TORQUE
1001 EXT1 COMMANDS 2= DI1,2 4= DI1P,2P,3 9= DI1F,2R 2= DI1,2 2= DI1,2 1= DI1 1= DI1 2= DI1,2
1002 EXT2 COMMANDS 0= NOT SEL 0= NOT SEL 0= NOT SEL 0= NOT SEL 7= DI6,5 6= DI6 6= DI6 2= DI1,2
1003 DIRECTION 3= REQUEST 3= REQUEST 3= REQUEST 3= REQUEST 3= REQUEST 1= FORWARD 1= FORWARD 3= REQUEST
1102 EXT1/EXT2 SEL 0= EXT10= EXT10= EXT10= EXT13= DI32= DI23= DI33= DI3
1103
REF1 SELECT 1= AI11= AI11= AI112=
DI3U,4D(NC)
1= AI11= AI11= AI11= AI1
1106
REF2 SELECT 2= AI22= AI22= AI22= AI22= AI219= PID1OUT 19 = PID1OUT 2= AI2
1201 CONST SPEED SEL 9= DI3,4 10 = DI4,5 9= DI3,4 5= DI5 0= NOT SEL 9= DI3,4 0= NOT SEL 4= DI4
1304
MINIMUM AI2 0.0% 0.0% 0.0% 0.0% 20.0% 20.0% 20.0% 20.0%
1401 RELAY OUTPUT 1 1= READY 1= READY 1= READY 1= READY 1= READY 1= READY 2= RUN 1= READY
1402 RELAY OUTPUT 2 2= RUN 2= RUN 2= RUN 2= RUN 2= RUN 2= RUN 3= FAULT(-1) 2= RUN
1403 RELAY OUTPUT 3 3= FAULT(-1) 3= FAULT(-1) 3= FAULT(-1) 3= FAULT(-1) 3= FAULT(-1) 3= FAULT(-1) 31 = PFC 3= FAULT(-1)
1501 AO1 CONTENT SEL 103 = 0103
OUTPUT FREQ
102 = 0102
SPEED
102 = 0102
SPEED
102 = 0102
SPEED
102 = 0102
SPEED
102 = 0102
SPEED
103 = 0103
OUTPUT FREQ
102 = 0102
SPEED
1507 AO2 CONTENT SEL 104 =
CURRENT
104 =
CURRENT
104 =
CURRENT
104 =
CURRENT
104 =
CURRENT
104 =
CURRENT
130 =
PID 1 FBK
104 =
CURRENT
1510 MINIMUM AO2 0.0 mA 0.0 mA 0.0 mA 0.0 mA 0.0 mA 0.0 mA 4.0 mA 0.0 mA
1601 RUN ENABLE 0= NOT SEL 0= NOT SEL 6= DI6 6= DI6 4= DI4 5= DI5 2= DI2 6= DI6
2201 ACC/DEC 1/2 SEL 5= DI50= NOT SEL 5= DI50= NOT SEL 0= NOT SEL 0= NOT SEL 0= NOT SEL 5= DI5
3201 SUPERV 1 PARAM 103 = 0103
OUTPUT FREQ
102 = 0102
SPEED
102 = 0102
SPEED
102 = 0102
SPEED
102 = 0102
SPEED
102 = 0102
SPEED
103 = 0103
OUTPUT FREQ
102 = 0102
SPEED
3401 SIGNAL1 PARAM 103 = 0103
OUTPUT FREQ
102 = 0102
SPEED
102 = 0102
SPEED
102 = 0102
SPEED
102 = 0102
SPEED
102 = 0102
SPEED
103 = 0103
OUTPUT FREQ
102 = 0102
SPEED
4001 GAIN 1.0 1.0 1.0 1.0 1.0 1.0 2.5 1.0
4002 INTEGRATION TIME 60.0 s 60.0 s 60.0 s 60.0 s 60.0 s 60.0 s 3.0 s 60.0 s
4101 GAIN 1.0 1.0 1.0 1.0 1.0 1.0 2.5 1.0
4102
INTEGRATION TIME 60.0 s 60.0 s 60.0 s 60.0 s 60.0 s 60.0 s 3.0 s 60.0 s
8123 PFC ENABLE 0= NOT SEL 0= NOT SEL 0= NOT SEL 0= NOT SEL 0= NOT SEL 0= NOT SEL 1= ACTIVE 0= NOT SEL